- www.circuitspecialists.com
220 S Country Club Drive #2
Mesa, AZ 85210
800-528-1417 / 480-464-2485
heath@cir.com

"Serving Customers for Over 35 Years."
 
Home - Test Equipment- FLUKE Test Equipment- Fluke 80 & 280 Series Digital Multimeters- Fluke 87V/E2 Industrial Electrician Combo Kit (FLUKE-87-5/E2)

FREE GIFT with qualifying purchase, CLICK for more information.



Fluke 87V/E2 Industrial Electrician Combo Kit (FLUKE-87-5/E2)

Part Number: FLUKE-87-5/E2
1 IN STOCK

For our current low price please call 1-800-528-1417
between 8:00AM & 5:00PM Mountain Standard Time (Monday-Friday).


Fluke 87V/E2 Industrial Electrician Combo Kit

This new combo kit is based on the Fluke 87V and includes special accessories to make industrial troubleshooting even more productive. Save over 15% compared with the individual purchase price of all the accessories.

Fluke 87V/E2 Industrial Electrician Combo Kit Includes:

Accuracy and diagnostic functions for maximum industrial productivity

The new Fluke 87V has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.

The 87 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection.

The new 87 series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.

Features

Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.

Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the new Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.

Complex PWM drive signals are not a problem for the Fluke 87V
Pulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second pulses can cause erratic behavior in some test equipment.
Specifications
Voltage DC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.1%+1)
  Fluke 87 V: ±(0.05%+1)
Maximum Resolution: Fluke 83 V: 100 µV
  Fluke 87 V: 10 µV
Voltage AC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.5%+2)
  Fluke 87 V: ±(0.7%+2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
  Fluke 87 V: 20kHz*
  *with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(0.4%+2)
  Fluke 87 V: ±(0.2%+2)
Maximum Resolution: Fluke 83 V: 0.01 mA
  Fluke 87 V: 0.01 µA
Current AC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(1.2%+2)
  Fluke 87 V: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA
Resistance
Maximum Resistance: 50 MΩ
Accuracy: Fluke 83 V: ±(0.4%+1)
  Fluke 87 V: ±(0.2%+1)
Maximum Resolution: 0.1Ω
Capacitance
Maximum Capacitance 9,999 µF
Accuracy ±(1%+2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ±(0.005%+1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ±(0.2% per khz +0.1%)
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/E: -200.0°C - 1090°C
  -328.0°F - 1994.0°F
  excluding probe
80 BK Temperature Probe
  -40.0°C - 260°C
  -40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range
Accuracy: Within ± (0.2% per kHz + 0.1 %)

Environmental Specifications
Operating Temperature
  -20°C to +55°C
Storage Temperature
  -40°C to +60°C
Humidity (Without Condensation)
  0% - 90% (0°C - 35°C)
  0% - 70% (35°C - 55°C)
Operating Altitude
  2000 m

Safety Specifications
Overvoltage category
  EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
  UL, CSA, TÜV, VDE listed

Mechanical & General Specifications
Size
  201 x 98 x 52 mm (with holster)
Weight
  355 g
Weigh With Holster and Flex-Stand
  624 g
Display
Digital: 6000 counts updates 4/sec.
  (Model 87 also has 19,999 counts in high-resolution mode.)
Analog: 32 segments, updates 40/sec.
Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
Warranty
  Lifetime
Battery Life
Alkaline: ~400 hours typical, without backlight
Shock
  1 Meter drop per IEC 61010-1:2001
Vibration
  Per MIL-PRF-28800 for a Class 2 instrument

Feature 83V 87V
True-rms ac voltage and current for accurate measurements on non linear signals  
Selectable filter for accurate voltage and frequency measurements on motor drives  
0.05 % dc accuracy  
6000 counts, 3-3/4 digits
4-1/2 digit mode for precise measurements (20,000 counts)  
Measure up to 1000 V ac and dc
Measure up to 10 A, 20 A for up to 30 seconds
Built in thermometer lets you carry one less tool (TC probe included)  
Frequency to 200 kHz and % duty cycle
Resistance, continuity and diode test
10,000 µF capacitance range for components and motor caps
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Peak capture to record transients as fast as 250 µs  
Relative mode to remove test lead interference from low ohms measurements
Auto and manual ranging for maximum flexibility
Touch Hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight for increased visibility
Analog bargraph for fast changing or unstable signals
Input Alert provides audible warning against wrong use of input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the calibration seal
"Classic" design with new removable holster with built in test lead and probe storage
Limited Lifetime warranty

View Product Manual