{"id":517,"date":"2013-07-19T13:54:51","date_gmt":"2013-07-19T20:54:51","guid":{"rendered":"http:\/\/blog.circuitspecialists.com\/?p=517"},"modified":"2014-06-20T11:33:11","modified_gmt":"2014-06-20T18:33:11","slug":"floating-oscilloscope-measurements-safety","status":"publish","type":"post","link":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/","title":{"rendered":"Floating Oscilloscope Measurements &#038; Safety"},"content":{"rendered":"<p>Oscilloscope users frequently need to take floating measurements in which neither point of the measurement is at ground potential. The signal common can be elevated to hundreds of volts from earth and, in addition, a number of these measurements must reject high common-mode signals.<\/p>\n<p>(A common-mode signal is a signal present at both points in a given circuit \u2014 identical in amplitude, frequency, and phase and referenced to ground. To make a floating measurement with a <a href=\"https:\/\/www.circuitspecialists.com\/digital-storage-oscilloscopes\">digital storage oscilloscope<\/a> necessitates the rejection of the common-mode signal, so that the instrument can display the difference signal.)<\/p>\n<p>Furthermore, unwanted ground current may add bothersome hum and ground loops. Unfortunately, users often resort to potentially dangerous measurement techniques to surmount these issues.<\/p>\n<p>Traditional oscilloscopes can\u2019t handle these issues alone. The majority of oscilloscopes have signal common terminals connected to the protective grounding system, which is done to ensure that all signals applied to or supplied from the instrument have one common connection point (typically the chassis). What this means is that measurements almost always should be made with respect to the earth ground, which in turn restrains a standard oscilloscope from measuring potential differences between two points, neither of which is at ground.<\/p>\n<p>The four safe solutions for these issues fall into four categories: battery-powered oscilloscopes, differential measurement systems, isolated-input oscilloscopes, and monolithic isolation amplifiers.<\/p>\n<p>Floating a ground-referenced <a href=\"https:\/\/www.circuitspecialists.com\/digital-storage-oscilloscopes\">oscilloscope<\/a> is a technique for \u201cdefeating\u201d the oscilloscope\u2019s protective grounding system by disconnecting signal common from the earth by either using an isolation transformer or mitigating the grounding system, which allows certain parts of the oscilloscope \u2014 namely the chassis, cabinet, and connectors \u2014 to cover the potential of the oscilloscope probe ground lead connection point.<\/p>\n<p>This process, however, is dangerous because of the instrument\u2019s elevated voltages and the cumulative stresses on the oscilloscope\u2019s power transformer insulation. Although such stress won\u2019t necessarily caused immediate failure, it may lead to future failures, including shock and fire hazards \u2014\u00a0even after properly grounding the oscilloscope once more. In addition to the dangerous nature of floating a ground-referenced oscilloscope, measurements taken using this technique are often inaccurate as a result of the total capacitance of the oscilloscope\u2019s chassis being connected straight to the circuit one is testing at the point where the common lead connects.<\/p>\n<p><a href=\"https:\/\/plus.google.com\/113447473195156867000\/posts?rel=author\" target=\"_blank\">Nick Jakubowski<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Oscilloscope users frequently need to take floating measurements in which neither point of the measurement is at ground potential. The<\/p>\n","protected":false},"author":42,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"colormag_page_layout":"default_layout","footnotes":""},"categories":[6],"tags":[],"class_list":["post-517","post","type-post","status-publish","format-standard","hentry","category-digital-storage-oscilloscope"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Floating Oscilloscope Measurements &amp; Safety | Simply Smarter Circuitry Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Floating Oscilloscope Measurements &amp; Safety | Simply Smarter Circuitry Blog\" \/>\n<meta property=\"og:description\" content=\"Oscilloscope users frequently need to take floating measurements in which neither point of the measurement is at ground potential. The\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\" \/>\n<meta property=\"og:site_name\" content=\"Simply Smarter Circuitry Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CircuitSpecialists\/\" \/>\n<meta property=\"article:published_time\" content=\"2013-07-19T20:54:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2014-06-20T18:33:11+00:00\" \/>\n<meta name=\"author\" content=\"George\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@CircuitSpecial\" \/>\n<meta name=\"twitter:site\" content=\"@CircuitSpecial\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"George\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\"},\"author\":{\"name\":\"George\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca\"},\"headline\":\"Floating Oscilloscope Measurements &#038; Safety\",\"datePublished\":\"2013-07-19T20:54:51+00:00\",\"dateModified\":\"2014-06-20T18:33:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\"},\"wordCount\":385,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#organization\"},\"articleSection\":[\"Digital Storage Oscilloscope\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\",\"name\":\"Floating Oscilloscope Measurements & Safety | Simply Smarter Circuitry Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#website\"},\"datePublished\":\"2013-07-19T20:54:51+00:00\",\"dateModified\":\"2014-06-20T18:33:11+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.circuitspecialists.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Floating Oscilloscope Measurements &#038; Safety\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#website\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/\",\"name\":\"Simply Smarter Circuitry Blog\",\"description\":\"How To&#039;s, Reviews, and Product News from Circuit Specialists HQ.\",\"publisher\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.circuitspecialists.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#organization\",\"name\":\"Circuit Specialists\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg\",\"contentUrl\":\"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg\",\"width\":120,\"height\":120,\"caption\":\"Circuit Specialists\"},\"image\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/CircuitSpecialists\/\",\"https:\/\/x.com\/CircuitSpecial\",\"https:\/\/www.youtube.com\/channel\/UCG87WTqDKIqA704uqjumJgg\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca\",\"name\":\"George\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g\",\"caption\":\"George\"},\"description\":\"George Leger has a Masters in Electrical Engineering from Stanford University, worked in private industry pioneering surface-mount technology and in government research labs for twenty years, published several papers on surface-mount technology, co-authored papers published in national symposiums on accelerator technology, was past president of SMTA and an adjunct professor at the community college level, holds a patent, and is a certified microchip design partner, serving as a consultant to many companies developing electronic circuits.\",\"sameAs\":[\"https:\/\/www.circuitspecialists.com\/\"],\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/author\/george\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Floating Oscilloscope Measurements & Safety | Simply Smarter Circuitry Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/","og_locale":"en_US","og_type":"article","og_title":"Floating Oscilloscope Measurements & Safety | Simply Smarter Circuitry Blog","og_description":"Oscilloscope users frequently need to take floating measurements in which neither point of the measurement is at ground potential. The","og_url":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/","og_site_name":"Simply Smarter Circuitry Blog","article_publisher":"https:\/\/www.facebook.com\/CircuitSpecialists\/","article_published_time":"2013-07-19T20:54:51+00:00","article_modified_time":"2014-06-20T18:33:11+00:00","author":"George","twitter_card":"summary_large_image","twitter_creator":"@CircuitSpecial","twitter_site":"@CircuitSpecial","twitter_misc":{"Written by":"George","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#article","isPartOf":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/"},"author":{"name":"George","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca"},"headline":"Floating Oscilloscope Measurements &#038; Safety","datePublished":"2013-07-19T20:54:51+00:00","dateModified":"2014-06-20T18:33:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/"},"wordCount":385,"commentCount":0,"publisher":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#organization"},"articleSection":["Digital Storage Oscilloscope"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/","url":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/","name":"Floating Oscilloscope Measurements & Safety | Simply Smarter Circuitry Blog","isPartOf":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#website"},"datePublished":"2013-07-19T20:54:51+00:00","dateModified":"2014-06-20T18:33:11+00:00","breadcrumb":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.circuitspecialists.com\/blog\/floating-oscilloscope-measurements-safety\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.circuitspecialists.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Floating Oscilloscope Measurements &#038; Safety"}]},{"@type":"WebSite","@id":"https:\/\/www.circuitspecialists.com\/blog\/#website","url":"https:\/\/www.circuitspecialists.com\/blog\/","name":"Simply Smarter Circuitry Blog","description":"How To&#039;s, Reviews, and Product News from Circuit Specialists HQ.","publisher":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.circuitspecialists.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.circuitspecialists.com\/blog\/#organization","name":"Circuit Specialists","url":"https:\/\/www.circuitspecialists.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg","contentUrl":"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg","width":120,"height":120,"caption":"Circuit Specialists"},"image":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/CircuitSpecialists\/","https:\/\/x.com\/CircuitSpecial","https:\/\/www.youtube.com\/channel\/UCG87WTqDKIqA704uqjumJgg"]},{"@type":"Person","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca","name":"George","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g","caption":"George"},"description":"George Leger has a Masters in Electrical Engineering from Stanford University, worked in private industry pioneering surface-mount technology and in government research labs for twenty years, published several papers on surface-mount technology, co-authored papers published in national symposiums on accelerator technology, was past president of SMTA and an adjunct professor at the community college level, holds a patent, and is a certified microchip design partner, serving as a consultant to many companies developing electronic circuits.","sameAs":["https:\/\/www.circuitspecialists.com\/"],"url":"https:\/\/www.circuitspecialists.com\/blog\/author\/george\/"}]}},"_links":{"self":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts\/517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/users\/42"}],"replies":[{"embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/comments?post=517"}],"version-history":[{"count":2,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts\/517\/revisions"}],"predecessor-version":[{"id":519,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts\/517\/revisions\/519"}],"wp:attachment":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/media?parent=517"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/categories?post=517"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/tags?post=517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}