{"id":720,"date":"2014-04-02T09:44:07","date_gmt":"2014-04-02T16:44:07","guid":{"rendered":"http:\/\/blog.circuitspecialists.com\/?p=720"},"modified":"2014-06-20T11:26:14","modified_gmt":"2014-06-20T18:26:14","slug":"dual-trace-oscilloscope-usage","status":"publish","type":"post","link":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/","title":{"rendered":"Dual-Trace Oscilloscope Usage"},"content":{"rendered":"<p>An <a title=\"oscilloscope\" href=\"https:\/\/www.circuitspecialists.com\/digital-storage-oscilloscopes\" target=\"_blank\">oscilloscope<\/a> is a piece of test equipment that enables technicians and electronic engineers to observe constantly varying signal voltages usually as a two-dimensional plot of two to four signals relative to time. A dual-trace oscilloscope is capable of plotting one or two signals simultaneously and features two independent input channels \u2014 one channel for each trace \u2014 each of which has its own connectors and controls. For the most part a dual-trace oscilloscope operates in the same manner as a single-trace oscilloscope, but multiple inputs and traces create greater complexity.<\/p>\n<p>Use a BNC cable to connect one signal oscillator to the channel one input on the oscilloscope and connect the second oscillator to the channel two input. Power up the oscilloscope and both signal oscillators and then adjust both oscillators\u2019 inputs to roughly two volts. Set one oscillator\u2019s frequency to 1,000 hertz and the other oscillator to 2,000 hertz. The frequencies don\u2019t need to be set to exact values.<\/p>\n<p>Next you will set the sweep control of the oscilloscope to one millisecond per division and set the triggering control to channel one. Adjust the vertical gain controls for both channels to one volt per division. Locate the display selector switch, which has options to display channel one, channel two, or both channels, and set it to display both oscilloscope channels. Use the vertical position controls to adjust the position of both signals. If necessary position the channel one trace directly above channel two\u2019s trace. Although the bottom signal trace may not be locked and stable, the top signal trace for channel one should be.<\/p>\n<p>Set the trigger control of the <a title=\"oscilloscope\" href=\"https:\/\/www.circuitspecialists.com\/digital-storage-oscilloscopes\" target=\"_blank\">oscilloscope<\/a> to channel two and observe the way the bottom trace stabilizes as the top trace starts to drift. Change the oscillators\u2019 frequencies and output waveforms which will affect one trace on the oscilloscope without changing the other trace.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>An oscilloscope is a piece of test equipment that enables technicians and electronic engineers to observe constantly varying signal voltages<\/p>\n","protected":false},"author":42,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"colormag_page_layout":"default_layout","footnotes":""},"categories":[1,6],"tags":[],"class_list":["post-720","post","type-post","status-publish","format-standard","hentry","category-all-posts","category-digital-storage-oscilloscope"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Dual-Trace Oscilloscope Usage | Simply Smarter Circuitry Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dual-Trace Oscilloscope Usage | Simply Smarter Circuitry Blog\" \/>\n<meta property=\"og:description\" content=\"An oscilloscope is a piece of test equipment that enables technicians and electronic engineers to observe constantly varying signal voltages\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\" \/>\n<meta property=\"og:site_name\" content=\"Simply Smarter Circuitry Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CircuitSpecialists\/\" \/>\n<meta property=\"article:published_time\" content=\"2014-04-02T16:44:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2014-06-20T18:26:14+00:00\" \/>\n<meta name=\"author\" content=\"George\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@CircuitSpecial\" \/>\n<meta name=\"twitter:site\" content=\"@CircuitSpecial\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"George\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\"},\"author\":{\"name\":\"George\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca\"},\"headline\":\"Dual-Trace Oscilloscope Usage\",\"datePublished\":\"2014-04-02T16:44:07+00:00\",\"dateModified\":\"2014-06-20T18:26:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\"},\"wordCount\":312,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#organization\"},\"articleSection\":[\"All Posts\",\"Digital Storage Oscilloscope\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\",\"name\":\"Dual-Trace Oscilloscope Usage | Simply Smarter Circuitry Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#website\"},\"datePublished\":\"2014-04-02T16:44:07+00:00\",\"dateModified\":\"2014-06-20T18:26:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.circuitspecialists.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Dual-Trace Oscilloscope Usage\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#website\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/\",\"name\":\"Simply Smarter Circuitry Blog\",\"description\":\"How To&#039;s, Reviews, and Product News from Circuit Specialists HQ.\",\"publisher\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.circuitspecialists.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#organization\",\"name\":\"Circuit Specialists\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg\",\"contentUrl\":\"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg\",\"width\":120,\"height\":120,\"caption\":\"Circuit Specialists\"},\"image\":{\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/CircuitSpecialists\/\",\"https:\/\/x.com\/CircuitSpecial\",\"https:\/\/www.youtube.com\/channel\/UCG87WTqDKIqA704uqjumJgg\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca\",\"name\":\"George\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g\",\"caption\":\"George\"},\"description\":\"George Leger has a Masters in Electrical Engineering from Stanford University, worked in private industry pioneering surface-mount technology and in government research labs for twenty years, published several papers on surface-mount technology, co-authored papers published in national symposiums on accelerator technology, was past president of SMTA and an adjunct professor at the community college level, holds a patent, and is a certified microchip design partner, serving as a consultant to many companies developing electronic circuits.\",\"sameAs\":[\"https:\/\/www.circuitspecialists.com\/\"],\"url\":\"https:\/\/www.circuitspecialists.com\/blog\/author\/george\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Dual-Trace Oscilloscope Usage | Simply Smarter Circuitry Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/","og_locale":"en_US","og_type":"article","og_title":"Dual-Trace Oscilloscope Usage | Simply Smarter Circuitry Blog","og_description":"An oscilloscope is a piece of test equipment that enables technicians and electronic engineers to observe constantly varying signal voltages","og_url":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/","og_site_name":"Simply Smarter Circuitry Blog","article_publisher":"https:\/\/www.facebook.com\/CircuitSpecialists\/","article_published_time":"2014-04-02T16:44:07+00:00","article_modified_time":"2014-06-20T18:26:14+00:00","author":"George","twitter_card":"summary_large_image","twitter_creator":"@CircuitSpecial","twitter_site":"@CircuitSpecial","twitter_misc":{"Written by":"George","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#article","isPartOf":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/"},"author":{"name":"George","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca"},"headline":"Dual-Trace Oscilloscope Usage","datePublished":"2014-04-02T16:44:07+00:00","dateModified":"2014-06-20T18:26:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/"},"wordCount":312,"commentCount":0,"publisher":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#organization"},"articleSection":["All Posts","Digital Storage Oscilloscope"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/","url":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/","name":"Dual-Trace Oscilloscope Usage | Simply Smarter Circuitry Blog","isPartOf":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#website"},"datePublished":"2014-04-02T16:44:07+00:00","dateModified":"2014-06-20T18:26:14+00:00","breadcrumb":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.circuitspecialists.com\/blog\/dual-trace-oscilloscope-usage\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.circuitspecialists.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Dual-Trace Oscilloscope Usage"}]},{"@type":"WebSite","@id":"https:\/\/www.circuitspecialists.com\/blog\/#website","url":"https:\/\/www.circuitspecialists.com\/blog\/","name":"Simply Smarter Circuitry Blog","description":"How To&#039;s, Reviews, and Product News from Circuit Specialists HQ.","publisher":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.circuitspecialists.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.circuitspecialists.com\/blog\/#organization","name":"Circuit Specialists","url":"https:\/\/www.circuitspecialists.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg","contentUrl":"https:\/\/www.circuitspecialists.com\/blog\/wp-content\/uploads\/2016\/03\/csi.jpg","width":120,"height":120,"caption":"Circuit Specialists"},"image":{"@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/CircuitSpecialists\/","https:\/\/x.com\/CircuitSpecial","https:\/\/www.youtube.com\/channel\/UCG87WTqDKIqA704uqjumJgg"]},{"@type":"Person","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/414c9adb626f1f36fba73f3b4ae376ca","name":"George","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.circuitspecialists.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f7719440cadb3ea0bf4a1ef0c50b309a?s=96&r=g","caption":"George"},"description":"George Leger has a Masters in Electrical Engineering from Stanford University, worked in private industry pioneering surface-mount technology and in government research labs for twenty years, published several papers on surface-mount technology, co-authored papers published in national symposiums on accelerator technology, was past president of SMTA and an adjunct professor at the community college level, holds a patent, and is a certified microchip design partner, serving as a consultant to many companies developing electronic circuits.","sameAs":["https:\/\/www.circuitspecialists.com\/"],"url":"https:\/\/www.circuitspecialists.com\/blog\/author\/george\/"}]}},"_links":{"self":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts\/720","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/users\/42"}],"replies":[{"embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/comments?post=720"}],"version-history":[{"count":3,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts\/720\/revisions"}],"predecessor-version":[{"id":723,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/posts\/720\/revisions\/723"}],"wp:attachment":[{"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/media?parent=720"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/categories?post=720"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.circuitspecialists.com\/blog\/wp-json\/wp\/v2\/tags?post=720"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}